does it have a "soft" switch, or a switch that actually disconnects the
batteries?
if it has a soft switch, then check the switching electronics....usually
it's a resistor that needs to be changed in value, a leaky transistor can
do it too.
If it's not a soft switch, then see if there is an electrolytic cap across
the battery connections-if so, it may be leaky.
Check for this, even if it IS using a soft switch-some of them do this too.
Another thought:how clean is the PC board.....flux and other junk on the
board, mixed with moisture could cause the same problem.


On Tue, Dec 13, 2011 at 5:33 PM, one6146 <one6146@yahoo.com> wrote:

> **
>
>
> I've got a problem with my highly precise, Auto-Ranging Digital Multimeter
> *. It uses 2 AA batts. The problem is that the bats die within a day if
> they are left in the device. I've got a leak somewhere..... Anyone ever
> have a similar problem??
>
> Thanks,
>
> klc
>
> * Radio Shack
>
>
>


[Non-text portions of this message have been removed]

------------------------------------

TO UNSUBSCRIBE: login to groups.yahoo.com, select group amateur-repairs, click on "leave group" on right side of screen and follow instructions. PLEASE do not send UNSUBSCRIBE messages to the list.Yahoo! Groups Links

<*> To visit your group on the web, go to:
http://groups.yahoo.com/group/Amateur-repairs/

<*> Your email settings:
Individual Email | Traditional

<*> To change settings online go to:
http://groups.yahoo.com/group/Amateur-repairs/join
(Yahoo! ID required)

<*> To change settings via email:
Amateur-repairs-digest@yahoogroups.com
Amateur-repairs-fullfeatured@yahoogroups.com

<*> To unsubscribe from this group, send an email to:
Amateur-repairs-unsubscribe@yahoogroups.com

<*> Your use of Yahoo! Groups is subject to:
http://docs.yahoo.com/info/terms/

No comments:

Post a Comment